;========================================================== ; GSD-File for Delta PD-01 ; ; Auto_Baud_supp, 12MBaud ; ; Stand : ; File : deltpd01.GSD ;=========================================================== #Profibus_DP ; Unit-Definition-List: GSD_Revision = 1 Vendor_Name = "Delta Electronics" Model_Name = "VFD DRIVES" Revision = "Rev. 1" Ident_Number = 0x08DB Protocol_Ident = 0 ; PROFIBUS DP Station_Type = 0 ; DP-slave FMS_supp = 0 Hardware_Release = "V1.0" Software_Release = "V1.0" Redundancy = 0 Repeater_Ctrl_Sig = 2 ; TTL 24V_Pins = 0 Implementation_Type = "SPC3" Bitmap_Device = "VFDDRV" Bitmap_Diag = "VFDDRV" Bitmap_SF = "VFDDRV" Slave_Family = 1@TdF@Delta VFD Drives ; Drives family ; Supported Communication Speeds: Auto_Baud_supp = 1 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 ; DP_Slave Information: Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 1 ; 100 micro-second ; Module-Definitions: Modular_Station = 1 ; 0-compact; 1-modular Max_Module = 1 Max_Input_Len = 32 Max_Output_Len = 32 Max_Data_Len = 64 Modul_Offset = 0 Fail_Safe = 0 Max_Diag_Data_Len = 16 ORDERNUMBER="PD-01" ;specify the user parameters: Max_User_Prm_Data_Len = 26 User_Prm_Data_Len = 26 User_Prm_Data = 0x20,0x00,\ 0x20,0x01,\ 0x00,0x00,\ 0x00,0x00,\ 0x21,0x01,\ 0x21,0x02,\ 0x21,0x03,\ 0x21,0x04,\ 0x00,0x01,\ 0x00,0x02,\ 0x00,0x02,\ 0x00,0x01,\ 0x00,0x00 Module = "4 PKW, 2 PZD (PPO 1) " 0xF3, 0xF1 EndModule Module = "0 PKW, 2 PZD (PPO 3) " 0x00, 0xF1 EndModule Module = "4 PKW, 4 PZD " 0xF3, 0xF3 EndModule Module = "0 PKW, 4 PZD " 0x00, 0xF3 EndModule ; Extended Description of User-Parameters PrmText = 1 Text(0) = "Address discontinuous" Text(1) = "Address continue" EndPrmText PrmText = 2 Text(0) = "Ignore and Continue" Text(1) = "Stop accord to Pr.STOP METHOD" EndPrmText PrmText = 3 Text(0) = "Stop DataExchange & Report Fault" Text(1) = "Continue & Report Alarm" Text(2) = "Ignore & Continue DataExchange" EndPrmText ExtUserPrmData = 1 "Data Input 1(PD-01 -> VFD)" Unsigned16 0x2000 0-65535 EndExtUserPrmData ExtUserPrmData = 2 "Data Input 2" Unsigned16 0x2001 0-65535 EndExtUserPrmData ExtUserPrmData = 3 "Data Input 3" Unsigned16 0x0000 0-65535 EndExtUserPrmData ExtUserPrmData = 4 "Data Input 4" Unsigned16 0x0000 0-65535 EndExtUserPrmData ExtUserPrmData = 5 "Data Output 1(VFD -> PD-01)" Unsigned16 0x2101 0-65535 EndExtUserPrmData ExtUserPrmData = 6 "Data Output 2" Unsigned16 0x2102 0-65535 EndExtUserPrmData ExtUserPrmData = 7 "Data Output 3" Unsigned16 0x2103 0-65535 EndExtUserPrmData ExtUserPrmData = 8 "Data Output 4" Unsigned16 0x2104 0-65535 EndExtUserPrmData ExtUserPrmData = 9 "d_state" Unsigned16 1 0-1 Prm_Text_Ref = 1 EndExtUserPrmData ExtUserPrmData = 10 "din_len" Unsigned16 2 0-4 EndExtUserPrmData ExtUserPrmData = 11 "dout_len" Unsigned16 2 0-4 EndExtUserPrmData ExtUserPrmData = 12 "LossDPComTreat" Unsigned16 1 0-1 Prm_Text_Ref = 2 EndExtUserPrmData ExtUserPrmData = 13 "LossSPComTreat" Unsigned16 0 0-2 Prm_Text_Ref = 3 EndExtUserPrmData Ext_User_Prm_Data_Ref(0) = 1 Ext_User_Prm_Data_Ref(2) = 2 Ext_User_Prm_Data_Ref(4) = 3 Ext_User_Prm_Data_Ref(6) = 4 Ext_User_Prm_Data_Ref(8) = 5 Ext_User_Prm_Data_Ref(10) = 6 Ext_User_Prm_Data_Ref(12) = 7 Ext_User_Prm_Data_Ref(14) = 8 Ext_User_Prm_Data_Ref(16) = 9 Ext_User_Prm_Data_Ref(18) = 10 Ext_User_Prm_Data_Ref(20) = 11 Ext_User_Prm_Data_Ref(22) = 12 Ext_User_Prm_Data_Ref(24) = 13 ;============ END of GSD file for VFD Drives =====================