Suited to stand alone single axis control applications:
-Motion control program with pre-programmed motion sequences
-Motion sequences can be freely chained or looped
-Control program selection and starting with sequence select inputs
-Program execution can be controlled by using conditional inputs
-Program execution can be monitored by using programable outputs
-Fixed logic inputs: Start Program, Stop Program, Drive Enable
-Selectable logic inputs: Homing Index, Limit Switch +, Limit Switch -, Fault Reset
Start Phasing, Seq Sel 1, Seq Sel 2, Seq Sel 3, Seq Sel 4, Seq Cond 1, Seq Cond 2,
Seq Cond 3, Seq Cond 4
-Selectable logic outputs: Motor Brake Control, Servo On Flag, Power Voltage On Flag
Phasing KO, Fault, Warning, Motor In Position Flag, Sequence On, Position reached,
Velocity reached, Seq Out 1, Seq Out 2, Seq Out 3, Seq Out 4
-Selectable analog inputs: motor current lmitation, profile speed modulation
-Programmable analog output (0-5V)